Do an Op-amps supply pins need to have the exact same nominal voltage?

The name of the pictureThe name of the pictureThe name of the pictureClash Royale CLAN TAG#URR8PPP











up vote
4
down vote

favorite
1












By power supply unit should ideally output +12 and -12V, however the readings are closer to 12.2V and -11.8V.



Is this likely to cause a problem, even though I only need an output range of 10V to -10V?










share|improve this question























  • The main problem is that you need +/-10V, but you have +/-12V
    – Eugene Sh.
    Aug 16 at 19:12










  • I will be limiting that in software, so shouldn't be a problem
    – 19172281
    Aug 16 at 19:13






  • 1




    You need to provide more information about what you are trying to do.
    – Eugene Sh.
    Aug 16 at 19:14






  • 1




    Op-amp is being used as a differential amplifier, with a voltage reference on one input, and a DAC output on the other, which should produce a -10v to 10v swing. The DAC output will be limited to ensure the voltage doesn't exceed +/10v.
    – 19172281
    Aug 16 at 19:17














up vote
4
down vote

favorite
1












By power supply unit should ideally output +12 and -12V, however the readings are closer to 12.2V and -11.8V.



Is this likely to cause a problem, even though I only need an output range of 10V to -10V?










share|improve this question























  • The main problem is that you need +/-10V, but you have +/-12V
    – Eugene Sh.
    Aug 16 at 19:12










  • I will be limiting that in software, so shouldn't be a problem
    – 19172281
    Aug 16 at 19:13






  • 1




    You need to provide more information about what you are trying to do.
    – Eugene Sh.
    Aug 16 at 19:14






  • 1




    Op-amp is being used as a differential amplifier, with a voltage reference on one input, and a DAC output on the other, which should produce a -10v to 10v swing. The DAC output will be limited to ensure the voltage doesn't exceed +/10v.
    – 19172281
    Aug 16 at 19:17












up vote
4
down vote

favorite
1









up vote
4
down vote

favorite
1






1





By power supply unit should ideally output +12 and -12V, however the readings are closer to 12.2V and -11.8V.



Is this likely to cause a problem, even though I only need an output range of 10V to -10V?










share|improve this question















By power supply unit should ideally output +12 and -12V, however the readings are closer to 12.2V and -11.8V.



Is this likely to cause a problem, even though I only need an output range of 10V to -10V?







op-amp negative-voltage






share|improve this question















share|improve this question













share|improve this question




share|improve this question








edited Aug 16 at 19:49









SamGibson

10.1k41436




10.1k41436










asked Aug 16 at 19:09









19172281

76111




76111











  • The main problem is that you need +/-10V, but you have +/-12V
    – Eugene Sh.
    Aug 16 at 19:12










  • I will be limiting that in software, so shouldn't be a problem
    – 19172281
    Aug 16 at 19:13






  • 1




    You need to provide more information about what you are trying to do.
    – Eugene Sh.
    Aug 16 at 19:14






  • 1




    Op-amp is being used as a differential amplifier, with a voltage reference on one input, and a DAC output on the other, which should produce a -10v to 10v swing. The DAC output will be limited to ensure the voltage doesn't exceed +/10v.
    – 19172281
    Aug 16 at 19:17
















  • The main problem is that you need +/-10V, but you have +/-12V
    – Eugene Sh.
    Aug 16 at 19:12










  • I will be limiting that in software, so shouldn't be a problem
    – 19172281
    Aug 16 at 19:13






  • 1




    You need to provide more information about what you are trying to do.
    – Eugene Sh.
    Aug 16 at 19:14






  • 1




    Op-amp is being used as a differential amplifier, with a voltage reference on one input, and a DAC output on the other, which should produce a -10v to 10v swing. The DAC output will be limited to ensure the voltage doesn't exceed +/10v.
    – 19172281
    Aug 16 at 19:17















The main problem is that you need +/-10V, but you have +/-12V
– Eugene Sh.
Aug 16 at 19:12




The main problem is that you need +/-10V, but you have +/-12V
– Eugene Sh.
Aug 16 at 19:12












I will be limiting that in software, so shouldn't be a problem
– 19172281
Aug 16 at 19:13




I will be limiting that in software, so shouldn't be a problem
– 19172281
Aug 16 at 19:13




1




1




You need to provide more information about what you are trying to do.
– Eugene Sh.
Aug 16 at 19:14




You need to provide more information about what you are trying to do.
– Eugene Sh.
Aug 16 at 19:14




1




1




Op-amp is being used as a differential amplifier, with a voltage reference on one input, and a DAC output on the other, which should produce a -10v to 10v swing. The DAC output will be limited to ensure the voltage doesn't exceed +/10v.
– 19172281
Aug 16 at 19:17




Op-amp is being used as a differential amplifier, with a voltage reference on one input, and a DAC output on the other, which should produce a -10v to 10v swing. The DAC output will be limited to ensure the voltage doesn't exceed +/10v.
– 19172281
Aug 16 at 19:17










3 Answers
3






active

oldest

votes

















up vote
11
down vote













If your op-amp can swing within 2.2V of the positive rail and within 1.8V of the negative rail under all possible load conditions, and if the inputs likewise are within the allowable common mode range then there is no problem.



There is no requirement for balanced voltages. You can use -0.1V and +20V if that works as indicated above (and, of course, if the op-amp can handle a 20.1V supply).






share|improve this answer



























    up vote
    0
    down vote













    The PSRR specs include DC meaning , other than saturation near the rails, if bipolar outputs , there is neglible influence.






    share|improve this answer



























      up vote
      0
      down vote













      If you operate within specifications your choice of +ve and -ve supply rail magnitudes is not that relevant.



      Usually systems are designed with same voltage but this is not a hard and fast rule. Often we see a few volts negative to handle ground references inputs and outputs and the positive supply common with other needs. Supplies of +12V and -5V would be common for reliable 0-5V operation.



      Your choice of OP amp or other components will dictate the power rails.



      If you need to operate at the mid point of the output swing and want to amplify ground referenced signals then you need to keep them equal magnitude.



      Some new OP amps can operate very close to the rails on input and/or output. These developments are the result of the drive for ever lower operating voltages. You cannot afford to loose 1.2V of headroom if your circuit is working with a 3V supply that you want to run from a single cell that is partially depleted.



      Most OP amps with single and dual rail operating specifications are inherently designed to handle uneven supplies. One of them is by design specified to be zero. Bypass, compensation and other circuitry has to be referenced to the correct point, often the negative rail so it works in both configurations.






      share|improve this answer




















        Your Answer




        StackExchange.ifUsing("editor", function ()
        return StackExchange.using("mathjaxEditing", function ()
        StackExchange.MarkdownEditor.creationCallbacks.add(function (editor, postfix)
        StackExchange.mathjaxEditing.prepareWmdForMathJax(editor, postfix, [["\$", "\$"]]);
        );
        );
        , "mathjax-editing");

        StackExchange.ifUsing("editor", function ()
        return StackExchange.using("schematics", function ()
        StackExchange.schematics.init();
        );
        , "cicuitlab");

        StackExchange.ready(function()
        var channelOptions =
        tags: "".split(" "),
        id: "135"
        ;
        initTagRenderer("".split(" "), "".split(" "), channelOptions);

        StackExchange.using("externalEditor", function()
        // Have to fire editor after snippets, if snippets enabled
        if (StackExchange.settings.snippets.snippetsEnabled)
        StackExchange.using("snippets", function()
        createEditor();
        );

        else
        createEditor();

        );

        function createEditor()
        StackExchange.prepareEditor(
        heartbeatType: 'answer',
        convertImagesToLinks: false,
        noModals: false,
        showLowRepImageUploadWarning: true,
        reputationToPostImages: null,
        bindNavPrevention: true,
        postfix: "",
        onDemand: true,
        discardSelector: ".discard-answer"
        ,immediatelyShowMarkdownHelp:true
        );



        );













         

        draft saved


        draft discarded


















        StackExchange.ready(
        function ()
        StackExchange.openid.initPostLogin('.new-post-login', 'https%3a%2f%2felectronics.stackexchange.com%2fquestions%2f391401%2fdo-an-op-amps-supply-pins-need-to-have-the-exact-same-nominal-voltage%23new-answer', 'question_page');

        );

        Post as a guest






























        3 Answers
        3






        active

        oldest

        votes








        3 Answers
        3






        active

        oldest

        votes









        active

        oldest

        votes






        active

        oldest

        votes








        up vote
        11
        down vote













        If your op-amp can swing within 2.2V of the positive rail and within 1.8V of the negative rail under all possible load conditions, and if the inputs likewise are within the allowable common mode range then there is no problem.



        There is no requirement for balanced voltages. You can use -0.1V and +20V if that works as indicated above (and, of course, if the op-amp can handle a 20.1V supply).






        share|improve this answer
























          up vote
          11
          down vote













          If your op-amp can swing within 2.2V of the positive rail and within 1.8V of the negative rail under all possible load conditions, and if the inputs likewise are within the allowable common mode range then there is no problem.



          There is no requirement for balanced voltages. You can use -0.1V and +20V if that works as indicated above (and, of course, if the op-amp can handle a 20.1V supply).






          share|improve this answer






















            up vote
            11
            down vote










            up vote
            11
            down vote









            If your op-amp can swing within 2.2V of the positive rail and within 1.8V of the negative rail under all possible load conditions, and if the inputs likewise are within the allowable common mode range then there is no problem.



            There is no requirement for balanced voltages. You can use -0.1V and +20V if that works as indicated above (and, of course, if the op-amp can handle a 20.1V supply).






            share|improve this answer












            If your op-amp can swing within 2.2V of the positive rail and within 1.8V of the negative rail under all possible load conditions, and if the inputs likewise are within the allowable common mode range then there is no problem.



            There is no requirement for balanced voltages. You can use -0.1V and +20V if that works as indicated above (and, of course, if the op-amp can handle a 20.1V supply).







            share|improve this answer












            share|improve this answer



            share|improve this answer










            answered Aug 16 at 19:33









            Spehro Pefhany

            195k4139388




            195k4139388






















                up vote
                0
                down vote













                The PSRR specs include DC meaning , other than saturation near the rails, if bipolar outputs , there is neglible influence.






                share|improve this answer
























                  up vote
                  0
                  down vote













                  The PSRR specs include DC meaning , other than saturation near the rails, if bipolar outputs , there is neglible influence.






                  share|improve this answer






















                    up vote
                    0
                    down vote










                    up vote
                    0
                    down vote









                    The PSRR specs include DC meaning , other than saturation near the rails, if bipolar outputs , there is neglible influence.






                    share|improve this answer












                    The PSRR specs include DC meaning , other than saturation near the rails, if bipolar outputs , there is neglible influence.







                    share|improve this answer












                    share|improve this answer



                    share|improve this answer










                    answered Aug 17 at 22:36









                    Tony EE rocketscientist

                    58k22085




                    58k22085




















                        up vote
                        0
                        down vote













                        If you operate within specifications your choice of +ve and -ve supply rail magnitudes is not that relevant.



                        Usually systems are designed with same voltage but this is not a hard and fast rule. Often we see a few volts negative to handle ground references inputs and outputs and the positive supply common with other needs. Supplies of +12V and -5V would be common for reliable 0-5V operation.



                        Your choice of OP amp or other components will dictate the power rails.



                        If you need to operate at the mid point of the output swing and want to amplify ground referenced signals then you need to keep them equal magnitude.



                        Some new OP amps can operate very close to the rails on input and/or output. These developments are the result of the drive for ever lower operating voltages. You cannot afford to loose 1.2V of headroom if your circuit is working with a 3V supply that you want to run from a single cell that is partially depleted.



                        Most OP amps with single and dual rail operating specifications are inherently designed to handle uneven supplies. One of them is by design specified to be zero. Bypass, compensation and other circuitry has to be referenced to the correct point, often the negative rail so it works in both configurations.






                        share|improve this answer
























                          up vote
                          0
                          down vote













                          If you operate within specifications your choice of +ve and -ve supply rail magnitudes is not that relevant.



                          Usually systems are designed with same voltage but this is not a hard and fast rule. Often we see a few volts negative to handle ground references inputs and outputs and the positive supply common with other needs. Supplies of +12V and -5V would be common for reliable 0-5V operation.



                          Your choice of OP amp or other components will dictate the power rails.



                          If you need to operate at the mid point of the output swing and want to amplify ground referenced signals then you need to keep them equal magnitude.



                          Some new OP amps can operate very close to the rails on input and/or output. These developments are the result of the drive for ever lower operating voltages. You cannot afford to loose 1.2V of headroom if your circuit is working with a 3V supply that you want to run from a single cell that is partially depleted.



                          Most OP amps with single and dual rail operating specifications are inherently designed to handle uneven supplies. One of them is by design specified to be zero. Bypass, compensation and other circuitry has to be referenced to the correct point, often the negative rail so it works in both configurations.






                          share|improve this answer






















                            up vote
                            0
                            down vote










                            up vote
                            0
                            down vote









                            If you operate within specifications your choice of +ve and -ve supply rail magnitudes is not that relevant.



                            Usually systems are designed with same voltage but this is not a hard and fast rule. Often we see a few volts negative to handle ground references inputs and outputs and the positive supply common with other needs. Supplies of +12V and -5V would be common for reliable 0-5V operation.



                            Your choice of OP amp or other components will dictate the power rails.



                            If you need to operate at the mid point of the output swing and want to amplify ground referenced signals then you need to keep them equal magnitude.



                            Some new OP amps can operate very close to the rails on input and/or output. These developments are the result of the drive for ever lower operating voltages. You cannot afford to loose 1.2V of headroom if your circuit is working with a 3V supply that you want to run from a single cell that is partially depleted.



                            Most OP amps with single and dual rail operating specifications are inherently designed to handle uneven supplies. One of them is by design specified to be zero. Bypass, compensation and other circuitry has to be referenced to the correct point, often the negative rail so it works in both configurations.






                            share|improve this answer












                            If you operate within specifications your choice of +ve and -ve supply rail magnitudes is not that relevant.



                            Usually systems are designed with same voltage but this is not a hard and fast rule. Often we see a few volts negative to handle ground references inputs and outputs and the positive supply common with other needs. Supplies of +12V and -5V would be common for reliable 0-5V operation.



                            Your choice of OP amp or other components will dictate the power rails.



                            If you need to operate at the mid point of the output swing and want to amplify ground referenced signals then you need to keep them equal magnitude.



                            Some new OP amps can operate very close to the rails on input and/or output. These developments are the result of the drive for ever lower operating voltages. You cannot afford to loose 1.2V of headroom if your circuit is working with a 3V supply that you want to run from a single cell that is partially depleted.



                            Most OP amps with single and dual rail operating specifications are inherently designed to handle uneven supplies. One of them is by design specified to be zero. Bypass, compensation and other circuitry has to be referenced to the correct point, often the negative rail so it works in both configurations.







                            share|improve this answer












                            share|improve this answer



                            share|improve this answer










                            answered Aug 18 at 18:39









                            KalleMP

                            3,441830




                            3,441830



























                                 

                                draft saved


                                draft discarded















































                                 


                                draft saved


                                draft discarded














                                StackExchange.ready(
                                function ()
                                StackExchange.openid.initPostLogin('.new-post-login', 'https%3a%2f%2felectronics.stackexchange.com%2fquestions%2f391401%2fdo-an-op-amps-supply-pins-need-to-have-the-exact-same-nominal-voltage%23new-answer', 'question_page');

                                );

                                Post as a guest













































































                                Popular posts from this blog

                                How to check contact read email or not when send email to Individual?

                                Bahrain

                                Postfix configuration issue with fips on centos 7; mailgun relay